Executing Standard
|
• CMC GB/T 7724-2008《Electronic Weighing Meter》PRC National Standard. |
• OMIL R76: 2006《Non-automatic Weighing Instruments》International Recommendation. |
• Accuracy Grade: III. |
• Number of Verification Intervals: 5,000. |
• Static Weighing Accuracy: 0.2‰. |
|
Structure & Configuration
|
• 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module. |
• Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash. |
Display & Operation |
• 16-bit Color screen with 800×480[7”] or 1024×600[10.2”] pixel and LED backlight. |
• Graphic display interface and touch operation. |
• Weight Display Range: -99,999~+999,999. |
• Scale Capacity: Setting Range 1~999,999. |
• Scale Division: Optional 1, 2, 5, 10, 20, 50. |
• Display Resolution: 1/100,000. |
• Weight Unit: Optional g, kg, t, lb[pound], kp[kilopound], UserSet. |
• Decimal Point: Optional 0, 0.0, 0.00, 0.000. |
|
Loadcell Interface
|
• Max. Connection Quantity: 8 Loadcells (350Ω). |
• Excitation Voltage/Max. Current: DC5V, 120mA. |
• Signal Input Range: 0~12.5mV. |
• Output Sensitivity of Loadcell: 1.0~2.5mV/V. |
• 24-bit Σ-△ADC with internal resolution 1/1,000,000. |
• Sampling Frequency: 800Hz. |
• Special anti-vibration digital filtering algorithm. |
• Zero Drift: ±0.1μV/℃ RTI (Relative to Input). |
• Gain Drift: ±5ppm/℃. |
• Non-linearity: 0.005%FS. |
|
Switch & Analog Signal Interface
|
• 9 Definable Normally Open Switch Inputs [DI]. |
• 18 Definable Normally Open Transistor Switch Outputs [DO]: DC24V, 1A. |
• 2 Definable Analog Signal Output [AO]: 0~10V/Max.50mA, Non-linearity: 0.05%FS. |
Reviews